Historical snapshotmid (2–5 yrs)Captured Oct 14, 2026, 1:04 a.m.

Power Generation Manager-Data Center (on-site in TN, IL, MI, WI, NM, or TX)

Oracle

Location
Nashville, TN, United States · Onsite
Compensation
Not stated in this snapshot
Employment
Not stated
Experience level
MID (2–5 years exp)
Specialization
Data Center, Data, Oracle
Source
Oracle

Role Overview

This position will be full-time on-site at OCI Headquarters in Nashville, TN, in Chicago, IL, or at one of the Oracle data center sites in Saline, MI; Doña Ana County, NM; or Port Washington, WI. Relocation assistance may be available in accordance with Oracle’s relocation policies. Candidates should expect a minimum of 50% travel , with additional travel as business needs require.<<

Oracle is seeking an experienced Power Generation Manager – The Power Generation Manager leads the strategy, reliability, maintenance, and operational readiness of backup power generation systems supporting mission-critical data center infrastructure. This role is the organization’s reciprocating-engine and generator subject matter expert, responsible for ensuring resilient, safe, and compliant operation of emergency power systems across the fleet.

Responsibilities

Key Responsibilities

Power Operations & Reliability

  • Lead and develop a team of power-generation subject matter experts, providing technical mentorship, performance coaching, and support across regions.
  • Own the global maintenance and reliability program for backup generators and all associated reciprocating-engine systems, including diesel, natural gas, dual-fuel, and other engine-driven emergency power equipment.
  • Establish and track fleet health metrics, reliability trends, failure modes, maintenance performance, and lifecycle risks; translate findings into prioritized improvement actions.
  • Develop and maintain maintenance scopes of work, operating procedures, technical standards, inspection plans, and service-provider requirements for generators and supporting equipment.
  • Provide deep technical oversight for reciprocating engines and generator systems, including prime movers, alternators, controls, starting systems, fuel systems, lubrication, cooling, air intake, turbocharging, exhaust, emissions equipment, and switchgear interfaces.
  • Lead complex root-cause investigations following generator failures, near misses, or adverse reliability trends; implement fleet-wide containment, corrective, and preventive actions.
  • Partner with original equipment manufacturers, vendors, and service providers to resolve systemic equipment issues, secure warranty or remediation commitments, and verify completion of corrective actions.
  • Collaborate with data center operations, critical facilities engineering, lifecycle management, construction, and procurement teams to improve backup-power design, operability, maintainability, and long-term reliability.
  • Deliver technical training for critical-facility engineers on operating, maintaining, testing, troubleshooting, and safely responding to issues involving emergency power systems.
  • Drive continuous-improvement initiatives that reduce operating costs, improve maintenance effectiveness, and increase generator availability and design reliability.
  • Ensure maintenance and operating programs meet applicable safety, environmental, regulatory, emissions, and business-continuity requirements.

Minimum Qualifications

  • Bachelor’s degree in mechanical engineering, Electrical Engineering, or a related technical discipline; or 10+ years of directly relevant, progressively responsible experience in reciprocating-engine power generation, critical facilities, industrial power, or a comparable high-availability environment.
  • Extensive experience managing or supporting reciprocating-engine-driven backup power systems in data centers, critical facilities, industrial plants, healthcare, utilities, or similarly high-availability environments.
  • Deep technical expertise with emergency generators and reciprocating engines, including diesel, natural-gas, and dual-fuel applications.
  • Strong working knowledge of engines, alternators, controls, fuel delivery, cooling, lubrication, intake and exhaust systems, turbochargers, batteries, starting systems, and generator paralleling or transfer interfaces.
  • Demonstrated experience leading failure investigations, reliability engineering efforts, corrective-action programs, and vendor escalations.
  • Proven people-leadership capability, including mentoring and developing technical experts across geographically distributed teams.
  • Strong analytical skills, with experience using maintenance and failure data to identify trends, develop metrics, and drive reliability improvements.
  • Experience creating technical standards, maintenance procedures, scopes of work, and training programs.
  • Excellent communication and stakeholder-management skills, including the ability to influence manufacturers, service providers, engineers, and senior operational leaders.

Preferred Qualifications

  • Experience supporting global data center operations and critical-facility infrastructure.
  • Familiarity with CMMS platforms, reliability-centered maintenance, FMEA/failure-mode analysis, and root-cause methodologies.
  • Professional certifications in reliability, power generation, critical facilities, or project management.

#LI-SS45

Application Instructions

Apply directly on Oracle Careers at Power Generation Manager-Data Center (on-site in TN, IL, MI, WI, NM, or TX).